Silt Density Index (SDI) Calculator

Silt density index (SDI) estimates particulate plugging of reverse-osmosis feedwater. Enter the times needed to collect the same sample volume at the start and after 5, 10 or 15 minutes. The calculator checks the 75% plugging limit and labels the test interval.

Formula

SDI_T = (1 − t₀ / t_T) × 100 / T

Worked example

Plugging = (1 − 30/60) × 100 = 50%. SDI15 = 50/15 = 3.33 %/min. The 50% plugging value is within the 75% calculation limit; compare the result with the installed membrane’s feedwater specification.

Test method

  1. Confirm the test setup Use the prescribed SDI apparatus, a 0.45 µm membrane and constant 30 psi (about 207 kPa) pressure. Follow the current test method and supplier instructions.
  2. Record the initial time Measure the seconds needed to collect the prescribed volume, commonly 500 mL, at the start of the test.
  3. Record the final time After the selected elapsed interval, time collection of the same volume. Keep pressure and other test conditions constant.
  4. Calculate and label the result Calculate plugging and divide by the elapsed minutes. If plugging exceeds 75%, repeat at a shorter permitted interval. Label SDI5, SDI10 or SDI15 explicitly.

What is the silt density index formula?

SDI_T = (1 − t₀/t_T) × 100/T. The two collection times use seconds; T is the elapsed test interval in minutes. Use the same collection volume at both measurements.

What is a good SDI for reverse osmosis?

Use your membrane manufacturer’s feedwater specification. For example, Hydranautics lists a maximum SDI15 of 5.0 for its ESPA2 MAX element, with potentially more conservative project limits. This is a product specification, not a universal regulatory limit or a guarantee against fouling.

Can I report SDI15 when plugging exceeds 75%?

No. Use a shorter permitted interval and report that interval explicitly. At 15 minutes, 75% plugging corresponds to SDI15 = 5; a larger calculated value is outside this plugging criterion.

Is SDI the same as turbidity?

No. Turbidity measures light scattering, while SDI measures plugging in a specific membrane test. Neither alone predicts all particulate, organic, biological or scaling fouling.

Sources

AquaPhoenix ASTM-based SDI test procedure (historical edition)Simple SDI: plugging limit and test intervalsHydranautics ESPA2 MAX feedwater specificationASTM D4189-07: historical scope and interpretation limits